Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.004
Filtrar
1.
Shanghai Kou Qiang Yi Xue ; 32(3): 251-254, 2023 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-37803978

RESUMO

PURPOSE: To evaluate the effect of different kinds of gingival retraction agents after directly contacted with polyvinyl siloxane impression materials on polymerization inhibition and the inhibition degree. METHODS: Five kinds of gingival retraction agents (0.1% epinephrine hydrochloride, 0.05% oxymetazoline, 15.5% ferric sulfate, 25% aluminum chloride and 5% aluminum chloride) were chosen, normal saline was as control group, and two kinds of polyvinyl siloxane impression materials (ExpressTM, ImprintTM Ⅱ) were combined into 12 groups. There were 12 specimens in each group and 144 specimens in total. Silicone rubber impression materials were mixed by the same operator using a dispensing gun into the acrylic mold, so that they could directly contact the gingival retraction agents on the densely woven cotton fabrics. The samples were removed when the polymerization time arrived according to the manufactures' recommendations and then placed under a stereomicroscope with a magnification of 10 times to observe whether polymerization inhibition occurred, the degree of inhibition was compared afterwards. SPSS 22.0 software package was used for statistical analysis. RESULTS: The polymerization inhibition of two kinds of silicone rubber impression materials occurred in 15.5% ferric sulfate group and 25% aluminum chloride group, and the inhibition occurrence rate was 100%, the difference was statistically significant (P<0.05) compared with normal saline group. Inhibition was not found in 0.1% epinephrine hydrochloride group, 0.05% oxymetazoline group and 5% aluminum chloride. The effect of 15.5% ferric sulfate and 25% aluminum chloride on polymerization inhibition degree of ImprintTM Ⅱ was greater than ExpressTM, and the difference was statistically significant(P<0.05). CONCLUSIONS: When silicone rubber impression material is used during impression procedure, attention should be paid to the effect of the gingival retraction agent containing 15.5% ferric sulfate and 25% aluminum chloride on its polymerization. The gingival retraction agent should be washed before impression to avoid the residue directly contacting the silicone rubber to prevent polymerization.


Assuntos
Oximetazolina , Elastômeros de Silicone , Cloreto de Alumínio , Elastômeros de Silicone/química , Polimerização , Solução Salina , Materiais para Moldagem Odontológica/química , Epinefrina/química , Técnica de Moldagem Odontológica
2.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 40(6): 662-667, 2022 Dec 01.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-36416318

RESUMO

OBJECTIVES: This work aimed to synthesize a novel injectable alginate impression material and evaluate its accuracy. METHODS: Certain proportions of sodium alginate, trisodium phosphate dodecahydrate, potassium fluorotitanate, diatomaceous earth, and other ingredients were dissolved in water and mixed evenly with a planetary centrifugal mixer to obtain a certain viscosity base paste. Certain proportions of calcium sulfate hemihydrate, magnesium oxide, glycerin, and polyethylene glycol (PEG) 400 were mixed evenly with a planetary centrifugal mixer to obtain the reactor paste with the same viscosity as the base paste. The base and reactor pastes were poured into a two-cylinder cartridge at a 2∶1 volume ratio. A gun device was used to accomplish mixing by compressing materials into a mixing tip. The samples were divided into three groups: injectable alginate impression materials (IA group) as the experimental group, and Jeltrate alginate impression materials (JA group) and Silagum-putty/light addition silicone rubber impression materials (SI group) as the two control groups. RESULTS: Scanning electron microscopy (SEM) showed that the injectable alginate impression materials had a denser structure and fewer bubbles than the commercial alginate impression material. The accuracy of the three kinds of impression materials was evaluated by 3D image superposition. The deviations between the three test group models and the standard model (trueness) were 49.58 µm±1.453 µm (IA group), 54.75 µm±7.264 µm (JA group), and 30.92 µm±1.013 µm (SI group). The deviations of the models within each test group (precision) were 85.79 µm±8.191 µm (IA group), 97.65 µm±11.060 µm (JA group), and 56.51 µm±4.995 µm (SI group). Significant differences in trueness and precision were found among the three kinds of impression materials (P<0.05). CONCLUSIONS: The accuracy of the new injectable alginate impression material was better than that of the traditional powder-type alginate impression material but worse than that of the addition silicone rubber impression materials. The novel injec-table alginate impression material demonstrated good operation performance and impression accuracy, showing broad application prospect.


Assuntos
Alginatos , Elastômeros de Silicone , Alginatos/química , Elastômeros de Silicone/química , Materiais para Moldagem Odontológica/química , Pós
3.
Indian J Dent Res ; 33(1): 30-36, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35946241

RESUMO

Objectives: The aims of this study were to compare the efficacy of two proven chemical disinfectants, glutaraldehyde and povidone iodine on dental impression and models by determining the reduction in the microbial load, and to compare changes in the physical properties of the models after adding the disinfectants. Materials and Methods: Irreversible hydrocolloid upper impressions of 90 patients were made and divided into 3 groups of 30 samples each; Group A--Control group; Impressions were run under clean tap water before pouring the model. Group B--2% Glutaraldehyde sprayed on the impression and left in situ for 10 min before pouring the model. Group C -10 ml of (5%) povidone iodine incorporated into the gypsum before pouring the model. Models from all three groups were subjected to microbiological assessment at three different time intervals, T0--24 h, T1--1 month and T2--3 months of storage by comparing the colony forming units (CFUs) of bacteria and fungi. The compressive strength of 5 models from each group was also analyzed in Newton's/mm2. Results: 2% Glutaraldehyde proved more effective than povidone iodine after 24 h of storage (T1), however at the end of 1 month (T1) and 3 months (T2) the Povidone group showed the maximum disinfection. Both the disinfectants caused a reduction in the compressive strength of the model with the povidone iodine group showing the maximum reduction. Conclusion: Although povidone iodine was the most effective disinfectant after 3 months, it showed a significant reduction in the compressive strength and caused discoloration of the model. 2% Glutaraldehyde proved to be the choice of disinfectant with minimal adverse effects.


Assuntos
Desinfetantes , Desinfecção , Desinfetantes de Equipamento Odontológico/química , Desinfetantes de Equipamento Odontológico/farmacologia , Materiais para Moldagem Odontológica/química , Técnica de Moldagem Odontológica , Desinfetantes/farmacologia , Glutaral/farmacologia , Humanos , Povidona-Iodo/farmacologia
4.
Am J Dent ; 35(2): 137-140, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35798708

RESUMO

PURPOSE: This in vitro study evaluated the effect of sodium carbonate (Na2CO3) concentration on adhesion between two layers of irreversible hydrocolloid wash impression material. METHODS: The first layer of irreversible hydrocolloid was brushed with three concentrations (0.1, 0.7, or 7.0 wt.%) of Na2CO3. Irreversible hydrocolloid not brushed with Na2CO3 was used as a negative control. Adhesion between the two layers (bond strength and adhesion energy) was then evaluated using a traction test, and the fracture modes were identified. The results of traction test were analyzed with a one-way ANOVA followed by a Tukey post hoc test. Chi-square test was used for analyzed failure mode after testing (α= 0.05). RESULTS: The bond strength (0.034 ±0.005 MPa) and adhesion energy (60.240 ±12.817 J.m⁻ ²) of the 0.7% Na2CO3 group were significantly higher than those of the other groups (P< 0.05). The 0.7% Na2CO3 group displayed only cohesive failure (ײ= 16; P< 0.0001). CLINICAL SIGNIFICANCE: Conditioning the surface of the first layer of irreversible hydrocolloid with 0.7% sodium carbonate improved adhesion between the two layers and may help clinicians improve the quality of the preliminary impressions of removable complete dentures.


Assuntos
Alginatos , Materiais para Moldagem Odontológica , Alginatos/química , Carbonatos , Coloides/química , Materiais para Moldagem Odontológica/química , Prótese Total , Teste de Materiais
5.
Biomed Res Int ; 2022: 1703869, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35187157

RESUMO

PURPOSE: To determine the hardness and Young's moduli of both commercial and experimental vinyl poly siloxane (VPS). METHODS: The purpose of this study was to develop a medium-bodied experimental (Exp-I, II, III, IV, and V) VPS impression materials and to analyse their effects on hardness and Young's modulus and compare them with three commercial VPS materials (Aquasil, Elite, and Extrude) using Shore A hardness tester. Measurements were recorded after 1, 24, 72, and 168 hours of mixing. The results were analysed with one-way ANOVA and post hoc Tukey's test using the SPSS PASW statistical 22 software. RESULTS: Commercial and experimental vinyl polysiloxane exhibited higher Shore A hardness values with time (i.e., 1 hour after mixing, 24 hours after mixing, 72 hours after mixing, and 1 week after mixing). All Comml and Exp VPS demonstrated a significant increase (ANOVA, p < 0.05) in hardness at increasing time points. Generally, all commercial VPS exhibited significantly higher values for Shore A hardness compared to all Exp formulations. For commercial products, Elt M presented significantly highest values at all-time points followed by Aq M then Extr M. Exp-I was significantly harder than all other Exp VPS at all-time points. Young's modulus values were directly related to Shore A hardness; materials with higher Shore A hardness values had higher Young's moduli. CONCLUSION: Continued polymerisation of elastomeric impression materials results in increased hardness over time. Hardness, Young's moduli, and rigidity of the set commercial and experimental VPS materials were within the required limits. Shore A hardness and Young's moduli were directly proportional to each other, and commercial and experimental materials had enough rigidity to contain the stone during pouring.


Assuntos
Materiais para Moldagem Odontológica/química , Polivinil/química , Siloxanas/química , Módulo de Elasticidade , Dureza , Teste de Materiais , Elastômeros de Silicone
6.
Mar Drugs ; 20(1)2022 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-35049910

RESUMO

This study aimed to investigate the potential use of brown algae Sargassum polycystum as irreversible hydrocolloid (alginate) impression material. Potassium alginate extracted from Sargassum polycystum was prepared in three different compositions (14%, 15%, and 16%) and mixed with other standard components to form an alginate impression material. Prior to that, the purity of potassium alginate was quantified with Fourier Transform Infrared Spectroscopy (FTIR) analysis. As a control material, the alginate impression material from a commercially available product was used. All alginate impression materials were then applied to a die stone model. Dimensional accuracy was measured by calculating the mesiodistal width of incisors in the generated dental cast using a digital caliper 0.01 accuracy (five replications). In addition, to evaluate the dimensional stability, the impression results were poured at four different periods (immediately, 5 min, 10 min, and 15 min). An independent t-test was performed to compare the measurement results with p < 0.05 considered significant. Analytical results confirm that the impression material containing 15% potassium alginate gives the best dimensional accuracy similar to control (p > 0.05). Meanwhile, the optimal dimensional stability was produced in the impression material containing 16% potassium alginate. Our study suggested that brown algae Sargassum polycystum has a promising potential to be used as an alginate impression material in clinical application.


Assuntos
Coloides/química , Materiais para Moldagem Odontológica/química , Sargassum , Animais , Organismos Aquáticos , Teste de Materiais
7.
Rev. ABENO ; 22(2): 1949, jan. 2022. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-1414019

RESUMO

O objetivo do presente estudo foi desenvolver um Objeto Virtual de Aprendizagem (OVA) sobre materiais de moldagem, com ênfase no alginato, e avaliar a influência do seu uso sobre o aprendizado teórico e habilidade clínica de estudantes de Odontologia, assim como sobre as propriedades física e mecânica material. Sessenta e quatro estudantes receberam aula teórica expositiva sobre alginato e posteriormente foram divididos em 2 grupos, Controle (n=30) e OVA (n=34). O grupo OVA teve acesso à ferramenta educacional composta de conteúdo teórico e simulação de espatulação do alginato, sendo sua habilidade avaliada. Todos os participantesrealizaram um pré-teste após a aula teórica, assim como testes de habilidade de manipulação do material,o qualfoi submetido a ensaio de resistência à compressão e reprodução de detalhes. Uma avaliação pós-teste foi realizada após quinze dias. Os resultados dos grupos foram comparados pelo teste t, modelo de regressão logística e as variáveis significativas foram incluídas no modelo de regressão múltipla. Todas as análises foram conduzidas com significância de 5%. Na simulação do OVA 75% dos usuários obtiveram nota máxima e os resultados das avaliações teóricas não indicaram diferença estatística entre os grupos. O uso do OVA está relacionado à maior habilidade clínica, com 3,76 mais chances de correta incorporação do pó. No ensaio de resistência à compressão a média dos grupos foi superior ao preconizado pela norma, OVA 0,86±0,03 e Controle 1,09±0,04. A ferramenta desenvolvida exerce influência positiva sobre a habilidade clínica e propriedade mecânica do material estudado, constituindo-se como promissora estratégia de aprendizagem virtual (AU).


The aim of the present study was to develop a Virtual Learning Object (VLO) on impression materials, with emphasis on alginate, and to evaluate the influence of its use on the theoretical learning and clinical skills of dental students, as well as on the physical properties and material mechanics. Sixty-four students received a theoretical lecture on alginate and were later divided into 2 groups, Control (n=30) and VLO (n=34). The VLO group had access to the educational tool composed of theoretical content and simulation of alginate mixing, and their ability was evaluated. All participants performed a pre-test after the theoretical class, as well as tests of ability to handle the material, which was subjected to a compressive strength test and detailreproduction. A post-test evaluation was performed after fifteen days. The results of the groups were compared by the t test, logistic regression model and significant variables were included in the multiple regression model. All analyzes were conducted with a significance of 5%. In the VLO simulation, 75% of the users obtained the maximum score and the results of the theoretical assessments did not indicate a statistical difference between the groups. The use of VLO is related to greater clinical skill, with 3.76 more chances of correct incorporation of the powder. In the compressive strength test, the mean of the groups was higher than that recommended by the standard, VLO 0.86±0.03 and Control 1.09±0.04. The developed tool has a positive influence on theclinical ability and mechanical property of the material studied, constituting itself as a promising strategy of virtual learning (AU).


Assuntos
Humanos , Masculino , Feminino , Educação a Distância/métodos , Materiais para Moldagem Odontológica/química , Materiais Dentários , Alginatos/química , Treinamento por Simulação/métodos , Estudantes de Odontologia , Modelos Logísticos , Competência Clínica , Aprendizagem Baseada em Problemas/métodos , Testes Mecânicos/métodos
8.
Acta odontol. latinoam ; 33(3): 221-227, Dec. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1278208

RESUMO

ABSTRACT The aim of this study was to evaluate the precision and accuracy of molds made with four commercial brands of alginate scanned at different times using digital model analysis. Eighty molds of a standard Typodont were made using 4 types of alginate (CCC: Cavex Color Change; IA: Identic Alginate; HY5: Hydrogum 5 and JP: Jeltrate Plus). The molds were scanned at four times: immediately (T1), 24h (T2), 72h (T3) and 120h (T4) after molding. Measurements were taken in three dimensions: anteroposterior, transverse and vertical. Significant differences in dimensional changes were noted between the materials over time (p <0.05). Anteroposterior dimensional variation was noted between times, especially for IA and JP. For transverse and vertical variables, a difference was found between the groups, especially at 24 h, 72 h and 120 h. CCC presented significant dimensional shrinkage only at T120 (transverse). IA and JP presented larger dimensional distortions in the vertical measurements. The molding materials used were not dimensionally stable when evaluated after 120 hours of molding. However, such evidence suggests that alginates with longer storage time, such as Cavex Color Change, are more accurate than conventional alginates.


RESUMO O objetivo do presente estudo foi avaliar a precisao e acurácia por meio de análise de modelos digitais de moldes digitalizados obtidos com quatro marcas comerciais de alginato em diferentes tempos. Oitenta moldes de um Typodont padrao foram obtidos utilizando 4 tipos de alginato (CCC: Cavex Color Change; IA: Identic Alginate; HY5: Hydrogum 5 e JP: Jeltrate Plus). Os moldes foram escaneados em quatro tempos: mediatamente (T1), 24h (T2), 72h (T3) e 120h (T4) após a moldagem. As medidas foram feitas em très dimensoes: ântero-posterior, transversal e vertical. Diferenças significativas nas mudanças dimensionais foram observadas entre os materiais ao longo do tempo (p <0,05). Variação dimensional ântero-posterior foi observada entre os tempos, principalmente para IA e JP. Para as variáveis transversal e vertical houve diferenga entre os grupos, principalmente em 24h, 72h e 120h. CCC apresentou contração dimensional significativa apenas em T120 (transversal). IA e JP apresentaram maiores distorções dimensionais na vertical. Os materiais de moldagem utilizados nao foram dimensionalmente estáveis quando avaliados após 120 horas de moldagem. No entanto, tais evidencias sugerem que os alginatos com maior tempo de armazenamento, como Cavex Color Change, sao mais precisos do que os alginatos convencionais.


Assuntos
Humanos , Materiais para Moldagem Odontológica/química , Modelos Dentários , Alginatos/química , Teste de Materiais , Técnica de Moldagem Odontológica
9.
PLoS One ; 15(10): e0240508, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33064731

RESUMO

OBJECTIVES: This study aimed to evaluate the marginal and internal gaps in 3D-printed interim crowns made from digital models of cone-beam computed tomography (CBCT) conversion data. MATERIALS AND METHODS: Sixteen polyvinylsiloxane impressions were taken from patients for single crown restorations and were scanned using CBCT. The scanning data were converted to positive Standard Triangulation Language (STL) files using custom-developed software. The fabricated stone models were scanned with an intraoral optical scanner (IOS) to compare the surface accuracy with the STL data obtained by CBCT. The converted STL files were utilized to fabricate interim crowns with a photopolymer using a digital light-processing 3D printer. The replica method was used to analyze the accuracy. The marginal and internal gaps in the replica specimen of each interim crown were measured with a digital microscope. The Friedman test and Mann-Whitney U test (Wilcoxon-signed rank test) were conducted to compare the measurements of the marginal and internal gaps with a 95% level of confidence. RESULTS: The root-mean-square values of the CBCT and IOS ranged from 41.00 to 126.60 µm, and the mean was 60.12 µm. The mean values of the marginal, internal, and total gaps were 132.96 (±139.23) µm, 137.86 (±103.09) µm, and 135.68 (±120.30) µm, respectively. There were no statistically significant differences in the marginal or internal gaps between the mesiodistal and buccolingual surfaces, but the marginal area (132.96 µm) and occlusal area (255.88 µm) had significant mean differences. CONCLUSION: The marginal gap of the fabricated interim crowns based on CBCT STL data was within the acceptable range of clinical success. Through ongoing developments of high-resolution CBCT and the digital model conversion technique, CBCT might be an alternative method to acquire digital models for interim crown fabrication.


Assuntos
Materiais para Moldagem Odontológica/química , Planejamento de Prótese Dentária/métodos , Polivinil/química , Siloxanas/química , Humanos , Modelos Anatômicos , Impressão Tridimensional , Software , Tomografia Computadorizada de Feixe Cônico Espiral/instrumentação
10.
Niger J Clin Pract ; 23(3): 284-290, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32134024

RESUMO

AIMS: The aim of this study was to determine the best approach to reduce the unfavorable change in the three different dimensions of impressions using disinfection durations of 15 and 30 min; three different disinfection procedures; and alginate impression products as research factors. MATERIALS AND METHODS: CA37, impressional, and cream alginate impressions were used; distortion in the AB, AC, and BC dimensions of impressions using disinfection durations of 15 and 30 min was studied; and no disinfection (ND), conventional disinfection (CD), and sonicator-activated disinfection (SAD) procedures were measured. RESULTS: Regarding AB dimension, the impressional has best performance when CD was applied for both 15 and 30 min. When SAD was applied for 15 min, impressional and cream alginates provide best performance. When CD was applied for 15 min, CA37 and impressional alginates provide best performance. Although ND-applied CA37 alginate after 30 min provides best performance, because of many outlier values, its implication may not be considered as meaningful. Regarding AC dimension, cream alginate has best performance when CD was applied for 15 min. The AC distances in all the alginates are considerably different from the base model after 30 min. Regarding BC dimension, only the CA37 alginate has the best performance when ND was applied for 15 min. All the alginates are considerably different from that of the base model after 30 min. CONCLUSION: Preference of 15-min disinfection can provide favorable results to obtain all impressions with minimally distorted dimensions. CD is an adequate procedure. The studied SAD needs to be developed further. All alginates are comparably successful to obtain impressions with desired distortion degrees.


Assuntos
Alginatos/química , Desinfetantes de Equipamento Odontológico/administração & dosagem , Desinfetantes de Equipamento Odontológico/química , Materiais para Moldagem Odontológica/química , Desinfecção/métodos , Esterilização/métodos , Técnica de Moldagem Odontológica , Humanos , Controle de Infecções Dentárias/métodos , Teste de Materiais/métodos , Modelos Dentários , Fatores de Tempo
11.
J Appl Biomater Funct Mater ; 18: 2280800019891072, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31986959

RESUMO

The aim of the study is to investigate the polymerization inhibition of elastomeric impression materials vinylpoly siloxane (VPS) and polyether (PE) when used in combination with retraction materials with and without subsequent cleaning with hydrogen peroxide (H2O2). Methods: Seven stainless steel specimens were fabricated. Four hundred and twenty impressions were made with three different elastomeric materials (140 each) as follows: group 1: VPS-Panasil; group 2: VPS-Express; group 3: PE-Monophase. Each material group was further subdivided into seven subgroups, based on use of no retraction material (control), three different retraction materials [Retraction capsule (RC3M), Dryz, Expasyl], and two cleaning techniques (water and H2O2). All subgroups included 20 impressions, which were made by a single operator using an automix gun. Evaluations were made using a visual scale by three calibrated examiners blindly and independently. Subjective categorization of the impressions were made as inhibited and uninhibited. Data were analyzed using Fisher's exact test and significance was set at p < 0.05. Results: Inhibited impressions were lower than uninhibited impressions among VPS materials (Panasil and Express); Panasil and Express showed comparable (p > 0.05) impression retardation. PE showed significantly higher inhibition compared to VPS materials (p < 0.05). Expasyl showed significantly higher polymerization inhibition than other retraction materials (p < 0.05). The use of H2O2 for cleaning showed significant reduction in polymerization inhibition than cleaning with water for Expasyl (p < 0.05). Conclusion: Overall contemporary retraction materials showed low potential for polymerization inhibition of elastomeric impression materials. Expasyl should be cleaned with H2O2 prior to impression making. However, Dryz and RC3M can show accurate impressions with water cleaning alone.


Assuntos
Materiais para Moldagem Odontológica/química , Peróxido de Hidrogênio/química , Teste de Materiais , Polimerização , Polivinil/química , Siloxanas/química , Aço Inoxidável/química
12.
Acta Odontol Latinoam ; 33(3): 221-227, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33523088

RESUMO

The aim of this study was to evaluate the precision and accuracy of molds made with four commercial brands of alginate scanned at different times using digital model analysis. Eighty molds of a standard Typodont were made using 4 types of alginate (CCC: Cavex Color Change; IA: Identic Alginate; HY5: Hydrogum 5 and JP: Jeltrate Plus). The molds were scanned at four times: immediately (T1), 24h (T2), 72h (T3) and 120h (T4) after molding. Measurements were taken in three dimensions: anteroposterior, transverse and vertical. Significant differences in dimensional changes were noted between the materials over time (p <0.05). Anteroposterior dimensional variation was noted between times, especially for IA and JP. For transverse and vertical variables, a difference was found between the groups, especially at 24 h, 72 h and 120 h. CCC presented significant dimensional shrinkage only at T120 (transverse). IA and JP presented larger dimensional distortions in the vertical measurements. The molding materials used were not dimensionally stable when evaluated after 120 hours of molding. However, such evidence suggests that alginates with longer storage time, such as Cavex Color Change, are more accurate than conventional alginates.


O objetivo do presente estudo foi avaliar a precisão e acurácia por meio de análise de modelos digitais de moldes digitalizados obtidos com quatro marcas comerciais de alginato em diferentes tempos. Oitenta moldes de um Typodont padrão foram obtidos utilizando 4 tipos de alginato (CCC: Cavex Color Change; IA: Identic Alginate; HY5: Hydrogum 5 e JP: Jeltrate Plus). Os moldes foram escaneados em quatro tempos: imediatamente (T1), 24h (T2), 72h (T3) e 120h (T4) após a moldagem. As medidas foram feitas em três dimensões: ântero-posterior, transversal e vertical. Diferenças significativas nas mudanças dimensionais foram observadas entre os materiais ao longo do tempo (p <0,05). Variação dimensional ântero-posterior foi observada entre os tempos, principalmente para IA e JP. Para as variáveis transversal e vertical houve diferença entre os grupos, principalmente em 24h, 72h e 120h. CCC apresentou contração dimensional significativa apenas em T120 (transversal). IA e JP apresentaram maiores distorções dimensionais na vertical. Os materiais de moldagem utilizados não foram dimensionalmente estáveis quando avaliados após 120 horas de moldagem. No entanto, tais evidências sugerem que os alginatos com maior tempo de armazenamento, como Cavex Color Change, são mais precisos do que os alginatos convencionais.


Assuntos
Alginatos/química , Materiais para Moldagem Odontológica/química , Modelos Dentários , Técnica de Moldagem Odontológica , Humanos , Teste de Materiais
13.
J Ayub Med Coll Abbottabad ; 32(Suppl 1)(4): S659-S667, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33754527

RESUMO

BACKGROUND: The goal of the current in vitro study was to assess the dimensional accuracy of dental impressions when stored at different times, temperature and humidity. METHODS: Impressions were poured to an aluminium triangular die and three teeth placed at the three corners of the die. A total of 130 impressions were made, in which 10 were poured immediately following manufacturers' instructions and the remaining 120 specimens were divided into two groups on the basis of relative humidity during storage. Group-1: 100%, Group-2: 50% relative humidity. Impression was poured with type IV gypsum. The below points were chosen to determine the length between in each of the specimens using the traveling microscope with 10x magnifications after 24 hours of model recovery for calculating the effect of changes in storage conditions- relative humidity, temperature and delay in pouring the impressions, on dimensional accuracy. RESULTS: Analysis of the results revealed that the casts achieved by pouring alginate impressions without delay were most accurate than the delay pouring. With the increase in temperature and time, the distance between the points increased and the casts obtained were bigger. CONCLUSION: Irreversible hydrocolloids should be poured immediately for optimum dimensional stability.


Assuntos
Alginatos/química , Materiais para Moldagem Odontológica/química , Sulfato de Cálcio/química , Coloides/química , Técnica de Moldagem Odontológica , Humanos , Umidade , Teste de Materiais , Temperatura , Dente/fisiologia
14.
J Ayub Med Coll Abbottabad ; 31(3): 359-363, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31535506

RESUMO

BACKGROUND: Irreversible hydrocolloid impression materials have been a staple in dentistry and useful for the fabrication of dental prosthesis. Gagging is most commonly experienced during maxillary impression making, which may affect the clinical management of the patient. Different techniques have been described to alleviate this problem. One of them is mixing lignocaine local anesthetic solution in irreversible hydrocolloid impression material before making the impression. The objective of this study was to evaluate the effect of lignocaine addition in irreversible hydrocolloid impression on the properties of irreversible hydrocolloid impression materials. METHODS: Irreversible hydrocolloid was mixed with water (Control group) or water and adrenalin (Lidocaine hydrochloride) (Experimental group). Compressive strength, tear strength and setting time were measured according to ISO1567 and ANSI/ADA specifications 18. The structural analysis of both groups was also evaluated by Fourier Transform Infrared Spectroscopy (FTIR). RESULTS: In the experimental group, insignificant decrease was observed in compressive and tear strength of irreversible hydrocolloid (p>0.05). There was significant (p<0.05) increase in setting time of irreversible hydrocolloid impression material. FTIR analysis indicated no change in chemistry of irreversible hydrocolloid before and after setting. CONCLUSIONS: Addition of lignocaine in irreversible hydrocolloid impression material may result in control of gag reflex without affecting its mechanical and chemical properties.


Assuntos
Anestésicos Locais/química , Coloides/química , Materiais para Moldagem Odontológica/química , Lidocaína/química , Humanos , Teste de Materiais , Espectroscopia de Infravermelho com Transformada de Fourier
15.
J Prosthodont ; 28(2): 195-201, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30427097

RESUMO

PURPOSE: To evaluate the accuracy of three digitization methods for the maxillary dental arch. MATERIALS AND METHODS: A maxillary typodont with various tooth preparation designs was used as the reference model. The scanned data were classified into direct scanning (DS), cast scanning (CS), and impression scanning (IS) groups according to the techniques applied for digitization (n = 10/group). An intraoral scanner was used for the DS group. Impressions obtained with polyether impression material were scanned with a tabletop scanner for the IS group. For the CS group, the definitive casts fabricated from the obtained impressions were scanned with the same tabletop scanner. The accuracy (trueness and precision) of the produced virtual dental casts was evaluated with specialized software. The full-arch and individual abutment deviations were measured with regard to root mean square error (RMSE) values. Data were analyzed with statistical software with an α = 0 . 05 . RESULTS: The RMSE values for both trueness and precision were lowest in the IS group, followed by the CS and DS groups, with statistically significant differences among the groups (p < 0.05). The trueness of individual abutments was significantly higher in the IS group than in the DS group. In addition, the trueness of individual abutments was affected by the location of the abutments in the DS group, whereas it did not differ between individual abutments in the CS and IS groups. CONCLUSIONS: These findings suggest that the IS method is an accurate digitization technique for the creation of a virtual dental cast.


Assuntos
Materiais para Moldagem Odontológica/química , Técnica de Moldagem Odontológica/instrumentação , Processamento de Imagem Assistida por Computador , Modelos Dentários , Simulação por Computador , Desenho Assistido por Computador , Arco Dental , Planejamento de Prótese Dentária , Precisão da Medição Dimensional , Imageamento Tridimensional , Técnicas In Vitro , Maxila
16.
J Prosthet Dent ; 121(1): 90-94, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30006216

RESUMO

STATEMENT OF PROBLEM: Although different impression techniques have been advocated for complete denture prosthodontics, objective studies that predict their effect on alveolar bone resorption are lacking. PURPOSE: The purpose of this prospective clinical pilot study was to objectively evaluate the effect of complete dentures fabricated by different impression techniques on mandibular residual ridge resorption in individuals with different bone mineral density. MATERIAL AND METHODS: Ninety-six participants with edentulism, selected according to inclusion criteria, underwent bone mineral density assessment and were divided into normal, osteopenic, and osteoporotic groups. Half of the participants in each group were provided with dentures fabricated by selective pressure impression technique (subgroup SIT), and the other half were provided with dentures fabricated by mucostatic impression technique (subgroup MIT). Computed tomographic scans of the mandible were made at denture delivery and 1 year after prosthesis use to assess alveolar bone height and width difference at marked locations at and after denture delivery. The data obtained were analyzed with the Student t test (α=.05). RESULTS: Significantly less reduction in mandibular ridge height and width was found in the MIT versus the SIT subgroups in both osteopenic and osteoporotic participants (P<.05). No significant subgroup difference was found for normal bone mineral density group, although resorption increased in height and width for the SIT subgroup. CONCLUSIONS: Mandibular residual ridge resorption was reduced for dentures fabricated using the mucostatic impression technique compared with the selective pressure impression technique in individuals with diminished bone density.


Assuntos
Densidade Óssea , Materiais para Moldagem Odontológica/química , Técnica de Moldagem Odontológica , Prótese Total Inferior , Muco , Adulto , Idoso , Perda do Osso Alveolar , Doenças Ósseas Metabólicas/complicações , Feminino , Humanos , Arcada Edêntula , Masculino , Mandíbula , Pessoa de Meia-Idade , Osteoporose/complicações , Projetos Piloto , Estudos Prospectivos , Tomógrafos Computadorizados
17.
Int. j. odontostomatol. (Print) ; 12(4): 368-375, dic. 2018. graf
Artigo em Inglês | LILACS | ID: biblio-975759

RESUMO

ABSTRACT: The aim of this study was to carry out a literature review on the accuracy of conventional and digital dental impression methods, as well as present the various three-dimensional intraoral scanning systems. A bibliographic search was carried out in PUBMED's main health database, in which works published between 2008 and 2018 were collected. Laboratory studies, case reports and systematic reviews were included, addressing topics that deal with conventional digital materials, impression and precision. Articles that did not evaluate impression materials, their behavior and techniques to obtain a good impression of oral structures were excluded. Through a review in the literature, obtained the following findings: the most critical stage in macking a dental prothesis is to take the dental impression. The conventional technique of impression consists of obtaining a negative copy of the intra-oral situation that will be poured into gypsum, obtaining a positive copy, on which the work will be carried out. Digital scanning systems were not superior to conventional moldings when comparing fidelity, accuracy and detail reproduction; in contrast, they were superior to conventional impression when considering clinical chair time, patient and operator preference, and patient comfort.


RESUMEN: El objetivo de este estudio consistió en realizar una revisión bibliográfica sobre la precisión de los métodos de moldeo dental convencionales y digitales, así como presentar los diversos sistemas de escaneo intraoral tridimensionales. Se realizó una búsqueda bibliográfica en la base de datos de salud principal de PUBMED en la cual se recopilaron trabajos publicados entre 2008 y 2018. Se incluyeron estudios de laboratorio, informes de casos y revisiones sistemáticas, abordando temas que tratan con materiales digitales convencionales, moldeo y precisión. Se excluyeron los artículos que no evaluaron los materiales de moldeo, su comportamiento y técnicas para obtener una buena impresión de las estructuras orales. A través de una revisión exhaustiva en la literatura, obtuvimos los siguientes hallazgos: el paso más crítico en la preparación de una pieza protésica es la impresión de la preparación. La técnica convencional de moldeo consiste en obtener una copia negativa de la situación intraoral que se verterá en el yeso, obteniendo una copia positiva, sobre la cual se realizará el trabajo. Resulta que los sistemas de escaneo digital no fueron superiores a las molduras convencionales al comparar la fidelidad, precisión y reproducción de detalles; en cambio, fueron superiores a las molduras convencionales al considerar el tiempo de trabajo clínico, la preferencia del paciente y del operador y la comodidad del paciente.


Assuntos
Humanos , Técnica de Moldagem Odontológica/classificação , Técnica de Moldagem Odontológica/instrumentação , Materiais para Moldagem Odontológica/química , Planejamento de Prótese Dentária , Impressão Tridimensional
18.
Dent Mater ; 34(12): e334-e343, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30318115

RESUMO

OBJECTIVES: To formulate experimental hydrophobic and hydrophilic vinyl polysiloxane (VPS) impression materials ab initio, comprising a novel cross-linking agent, tetra-functional (dimethylsilyl) orthosilicate (TFDMSOS), and a non-ionic surfactant, Rhodasurf CET-2 (ethoxylatedcetyl-oleyl alcohol), and to investigate their effects on tear strength (TS). METHODS: Five experimental formulations (Exp I-V) were prepared and compared with three medium bodied commercial VPS impression materials (Aq M, Elt M, Extr M). Tear test was performed on trouser test specimens (n=12 per material), at four time points (immediately, 24, 72 and 168 hours after setting). FTIR spectroscopy was used for identifying functional bonds and cross-linking. The results were analysed with one-way ANOVA, two-way ANOVA and post hoc Tukey's test using the SPSS PASW statistical 22 software. RESULTS: The material with novel cross-linking agent (Exp II) had significantly higher TSs at all-time points compared to Exp I (control; p˂0.05). Materials incorporating both TFDMSOS and surfactant (Exp III, IV and V), had further significantly increased TS at all-time points, which were concentration dependent. Extr M had a significantly lower TS (immediately after setting and at 24 hours) compared to all Exp and other commercial materials, with the exception of Elt M (difference not significant). The TSs of Exp II-V, after 72 and 168 hours, were significantly higher for than all commercial products and Exp I. FTIR spectra showed the consumption of Si-H groups indicating crosslinking had taken place with the addition of TFDMSOS and surfactant which contributed to an increase in the TS. SIGNIFICANCE: TFDMSOS cross-linking agent increased the TS of Exp II significantly at all-time points compared to the control. Novel surfactant further significantly increased TS, and it was also concentration dependent. Exp VPS with improved TS have been developed, addressing one of the drawbacks of commercial VPS materials.


Assuntos
Reagentes de Ligações Cruzadas/química , Materiais para Moldagem Odontológica/química , Polivinil/química , Siloxanas/química , Tensoativos/química , Técnica de Moldagem Odontológica , Interações Hidrofóbicas e Hidrofílicas , Ácidos Oleicos/química , Espectroscopia de Infravermelho com Transformada de Fourier
19.
Dent Med Probl ; 55(1): 43-48, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30152634

RESUMO

BACKGROUND: Alginates are impression materials commonly used in prosthodontics and orthodontics. However, all these materials have some disadvantages, such as limited elasticity, tearing resistance and low dimensional stability. OBJECTIVES: The aim of this research was to investigate the effect of various water quantities and qualities on changes in the properties of alginates. MATERIAL AND METHODS: Two alginates, Neocolloid and Tulip, were mixed with different volumes of water, water with calcium ions, or sparkling water with CO2. The dimensions, setting times, and hardness of the specimens were measured and Young's modulus was calculated. The significance of the difference between the mean values of different groups and the control group was assessed by Student's t-test or the Mann-Whitney U test. RESULTS: The dimensional stability changes of both alginate impression materials were statistically dependent on the quantity of water used for mixing. Sample storage over 24 h of samples prepared with +15% water led to 5.00% shrinkage for Neocolloid and 4.41% for Tulip. The setting times of Neocolloid and Tulip were significantly prolonged when the alginates were prepared with +15% water; the addition of calcium ions shortened the setting times of both alginates. Specimens mixed with the water containing Ca2+ ions were characterized by greater hardness and Young's modulus values when compared to the alginate mixed with distilled water. CONCLUSIONS: For mixing alginates, it is necessary to use the manufacturers' recommended mixing ratios between powder and water. To obtain the right setting time, hardness and elasticity, the application of distilled or demineralized water is advised.


Assuntos
Alginatos/química , Materiais para Moldagem Odontológica/química , Qualidade da Água , Água/química , Cálcio/análise , Dióxido de Carbono/análise , Dureza , Humanos , Íons/análise
20.
Dent Mater J ; 37(5): 818-824, 2018 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-29962413

RESUMO

This study evaluated the wettability of commercial vinyl polysiloxane impression materials by measuring contact angles on horizontal and non-horizontal surfaces using artificial saliva. Three light bodies (Affinis [Affi], Silagum [Sila] and Variotime [Vario-LB]) and one extra light body (Viriotime [Vario-ELB]) were prepared with flat surfaces. Static and dynamic contact angles were measured using the sessile drop method as a function of time. Contact angle hysteresis was the value of advancing contact angle minus receding contact angle. The results indicated that all materials were classified as hydrophilic materials. Vario-ELB and Affi showed better initial wettability than the other two materials. Vario-ELB showed more hydrophilic properties and was more vulnerable to changes in the intraoral environment compared to Affi, Sila and Vario-LB. These results suggest that measuring the time-dependent dynamic contact angle on the inclined surface can provide effective information regarding the wettability of impression materials to evaluate their clinical performance.


Assuntos
Materiais para Moldagem Odontológica/química , Polivinil/química , Saliva Artificial/química , Siloxanas/química , Materiais para Moldagem Odontológica/classificação , Teste de Materiais , Propriedades de Superfície , Fatores de Tempo , Molhabilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...